| Server IP : 45.40.142.9 / Your IP : 216.73.216.250 Web Server : Apache System : Linux s45-40-142-9.secureserver.net 2.6.32-754.35.1.el6.x86_64 #1 SMP Sat Nov 7 12:42:14 UTC 2020 x86_64 User : bayspec ( 506) PHP Version : 5.6.40 Disable Function : NONE MySQL : ON | cURL : ON | WGET : ON | Perl : ON | Python : ON | Sudo : ON | Pkexec : ON Directory : /proc/self/root/usr/share/doc/libxml2-python-2.7.6/ |
Upload File : |
#!/usr/bin/python -u
# -*- coding: ISO-8859-1 -*-
#
# this tests the next API of the XmlTextReader interface
#
import libxml2
import StringIO
import sys
# Memory debug specific
libxml2.debugMemory(1)
f = StringIO.StringIO("""<a><b><c /></b><d>content of d</d></a>""")
input = libxml2.inputBuffer(f)
reader = input.newTextReader("test_next")
ret = reader.Read()
if ret != 1:
print "test_next: Error reading to first element"
sys.exit(1)
if reader.Name() != "a" or reader.IsEmptyElement() != 0 or \
reader.NodeType() != 1 or reader.HasAttributes() != 0:
print "test_next: Error reading the first element"
sys.exit(1)
ret = reader.Read()
if ret != 1:
print "test_next: Error reading to second element"
sys.exit(1)
if reader.Name() != "b" or reader.IsEmptyElement() != 0 or \
reader.NodeType() != 1 or reader.HasAttributes() != 0:
print "test_next: Error reading the second element"
sys.exit(1)
ret = reader.Read()
if ret != 1:
print "test_next: Error reading to third element"
sys.exit(1)
if reader.Name() != "c" or reader.NodeType() != 1 or \
reader.HasAttributes() != 0:
print "test_next: Error reading the third element"
sys.exit(1)
ret = reader.Read()
if ret != 1:
print "test_next: Error reading to end of third element"
sys.exit(1)
if reader.Name() != "b" or reader.NodeType() != 15:
print "test_next: Error reading to end of second element"
sys.exit(1)
ret = reader.Next()
if ret != 1:
print "test_next: Error moving to third element"
sys.exit(1)
if reader.Name() != "d" or reader.IsEmptyElement() != 0 or \
reader.NodeType() != 1 or reader.HasAttributes() != 0:
print "test_next: Error reading third element"
sys.exit(1)
ret = reader.Next()
if ret != 1:
print "test_next: Error reading to end of first element"
sys.exit(1)
if reader.Name() != "a" or reader.IsEmptyElement() != 0 or \
reader.NodeType() != 15 or reader.HasAttributes() != 0:
print "test_next: Error reading the end of first element"
sys.exit(1)
ret = reader.Read()
if ret != 0:
print "test_next: Error reading to end of document"
sys.exit(1)
#
# cleanup for memory allocation counting
#
del f
del input
del reader
# Memory debug specific
libxml2.cleanupParser()
if libxml2.debugMemory(1) == 0:
print "OK"
else:
print "Memory leak %d bytes" % (libxml2.debugMemory(1))
libxml2.dumpMemory()